April 11, 2002
Mr. Michael D. Kiser
FLAME SEAL PRODUCTS INC.
4025 Willowbend Blvd., #310
Houston, TX 77025
Reference: Flammability Test
Report
Lab Identification No. 3292
Invoice No. 6133
Dear Mr. Kiser:
One (1) fabric sample, identified
as " UPHOLSTERY
FABRIC
(50% COTTON, 50% POLYESTER BLEND) TREATED WITH FLAME SEAL'S FABRIC
SEAL-
(S)", was received and tested in accordance with the National
Fire
Prevention Association No. 701, "Standard Methods of Fire Tests
for
Flame
Propagation of Textiles and Films, 1999 Edition (Test 1,
Small
Scale)". The results are as follows:
The results are as follows:
|
Specimen Number
|
Residual
Flame
(seconds)
|
Weight Loss
(percent)
|
|
1
|
0.0
|
12.73
|
|
2
|
0.0
|
8.86
|
|
3
|
0.0
|
12.32
|
|
4
|
0.0
|
8.26
|
|
5
|
0.0
|
12.09
|
|
6
|
0.0
|
7.95
|
|
7
|
0.0
|
9.76
|
|
8
|
0.0
|
7.78
|
|
9
|
0.0
|
8.40
|
|
10
|
0.0
|
5.82
|
| |
--------------
|
--------------
|
|
AVG.
|
0.0
|
9.39
|
The fabric sample submitted meets
the minimum
requirements
of the above standard. The average percent weight loss cannot
exceed
40% and the weight loss of individual specimens cannot exceed mean
value
plus three standard deviations. The average residual flame cannot
exceed 2.0 seconds.
If
there are any questions or when we can be of
further
assistance, please let us know.

|