EMERGENCY TELEPHONE NO.: 800-424-9300
PRODUCT NAME:
PAPER
SEAL ™
FIRE RETARDANT
CHEMICAL FAMILY: Aqueous
based fire
retardant
penetrant /coating.
HMIS CODES: Health:1,
Flammability:0, Reactivity:0, PPE: B
SECTION I -
PRODUCT INFORMATION
MANUFACTURER'S NAME:
FLAME SEAL PRODUCTS, INC.
4025 WILLOWBEND BLVD. #310
HOUSTON, TX 77025 USA
TELEPHONE # FOR INFORMATION:
713-668-4291
SECTION II -
HAZARDOUS COMPONENTS
| COMPONENT |
|
ACGIH |
OSHA |
| CAS REGISTRY NO. |
WT. % |
TLV |
PEL |
Sodium Bromide
7647-15-6 |
5% - 9% |
Not
Established
|
Not Established
|
Boric Acid
10043-35-3 |
0.5% - 2% |
10
mg/m3
|
Cal OSHA PEL 10mg/m3
Osha PEL (Total Dust) 15mg/m3
Osha PEL (Respirable Dust) 5mg/m3 |
SECTION III -
PHYSICAL PROPERTIES
APPEARANCE AND ODOR:
Clear, odorless
liquid.
MOLECULAR WEIGHT: Not
Applicable.
BOILING POINT: (DEGREES
FAHRENHEIT): 212
-
Not accurate: mixture of components.
MELTING POINT: (DEGREES
FAHRENHEIT): Not
Applicable.
VAPOR PRESSURE: (mm of
Mercury): Not
Determined.
SPECIFIC GRAVITY
(WATER=1): 1.08-1.11
VAPOR DENSITY (AIR=1):
Not determined.
PERCENT VOLATILE: (BY
WEIGHT): 84% max.
(water
content only)
pH: 5.5 - 6.7
SOLUBILITY IN WATER:
Complete.
EVAPORATION RATE: (BUTYL
ACETATE=1):
Not Determined.
STORAGE:
Temperature- 40-90°F,
(4.44°C-32.22°C) , Time – 1 Year from Manufacturer Date
SECTION IV - FIRE
AND EXPLOSION DATA
FLASH POINT (DEGREES FAHRENHEIT:
PENSKY-MARTENS
CLOSED
CUP): None to boiling.
FIRE EXTINGUISHING MEDIA: Not
combustible. Use water
spray,
fog, foam, dry chemicals, CO2, or other agents as
appropriate
for material in surrounding fire.
FLAMMABLE LIMITS (PERCENT BY
VOLUME): Not applicable.
SPECIAL FIRE FIGHTING PROCEDURES
AND EQUIPMENT: Not
combustible.
Use safety equipment and clothing which is suitable for materials in
surrounding
fire.
UNUSUAL FIRE AND EXPLOSION
HAZARDS: None
HAZARDOUS COMBUSTION PRODUCTS:
Combustion products
can
include carbon dioxide, carbon monoxide, oxides of phosphorus and
traces
of ammonia.
SECTION V -
REACTIVITY DATA
STABILITY:
STABLE ___X___
UNSTABLE _______
CONDITIONS TO AVOID:
Storage of “liquid”
in
containers other than plastic, stain-less steel or glass. Contamination
with strong oxidizers, strong alkali or strong acids.
INCOMPATIBILITY (MATERIALS TO
AVOID):
Strong
oxidizers, alkalis, or acids. When in liquid state the product slowly
reacts
with some common metals causing flammable hydrogen gas to be emitted.
HAZARDOUS DECOMPOSITION
PRODUCTS:
Not
applicable.
HAZARDOUS
POLYMERIZATION:
Will Occur _______
Will Not Occur ___X___
SECTION VI -
HEALTH HAZARD
INFORMATION
EXPOSURE FROM ROUTINE USE: No
evidence of adverse
effects
from available information.
EFFECTS OF OVEREXPOSURE: EYES. . .
Direct contact or
prolonged
exposure to mist may cause redness and pain. NOSE. .
. Breathing of heavy concentrations of mists may cause sinus irritation
and dizziness. MOUTH. . . Ingestion may cause
nausea.
SKIN. . . Prolonged contact may cause reddening of effected area.
PROBABLE ROUTES OF
EXPOSURE: Skin,
eyes,
inhalation, and ingestion.
EMERGENCY AND FIRST AID PROCEDURES:
EYE CONTACT:
Immediately flush eyes with
water for at least 15 min. including underneath
eyelids.
Consult a physician if irritation persists.
INHALATION: Remove
to fresh air
immediately.
Use adequate ventilation.
INGESTION:
Substance exhibits
very low
toxicity. Consult a physician if upset stomach
or
nausea occur.
SECTION
VII - TOXICITY
DATA
ORAL: Acute Oral Toxicity: Ld50
(rat) > 5000 mg/kg
DERMAL: Not established, not
expected to be harmful.
May
be irritating with continual contact.
INHALATION: Not established. Not
expected to be
harmful.
If necessary, use respirator (if adequate ventilation is not available)
to keep exposure to particulate matter at a minimum.
OTHER PERTINENT DATA: Not
applicable.
SECTION VIII -
SPECIAL PROTECTION
INFORMATION
PERSONAL PROTECTION EQUIPMENT
PROTECTIVE GLOVES: Wear impervious
gloves as
necessary
to avoid excessive skin contact: i.e. rubber or
neoprene.
EYE PROTECTION: Protective
glasses or goggles in
heavy
mist areas.
RESPIRATORY PROTECTION (SPECIFY
TYPE): For heavy
mist
exposure use a NIOSH/MSHA approved respirator
suitable
for use with organic vapors if proper ventilation
can not be provided.
OTHER PROTECTIVE EQUIPMENT:
Adequate clothing to
minimize
direct contact with skin.
VENTILATION
LOCAL EXHAUST: Use exhaust fans if
necessary to
control
mist or vapor.
MECHANICAL (GENERAL): Normal room
ventilation of
fans.
SPECIAL: Not applicable.
SECTION IX -
SPILL, LEAK, AND
DISPOSAL
PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL
IS RELEASED OR
SPILLED:
Confine spilled material and absorb on sand, sawdust, earth or other
available
solids. Sweep and place in a suitable container. Flush with water and
rinse
minor spills into sewer if permitted by Federal, State and local
regulations.
WASTE DISPOSAL METHODS: Incinerate
or bury in a
suitable
land fill where permitted by appropriate government regulations.
CLEAN WATER ACT REQUIREMENTS:
Section 311 of the
Clean
Water Act lists phosphorus as a hazardous substance which, if
discharged
into or upon water, will present an imminent and substantial danger to
public health and welfare. Spills of 5000 pounds or more must be
reported
to the National Response Center @ 1-800-424-8802.
RESOURCE CONSERVATION AND RECOVERY
ACT (RCRA)
REQUIREMENTS:
No applicable information found.
SECTION X -
REGULATORY INFORMATION
FDA: No applicable information
found.
USDA: No applicable information
found.
CPSC: No applicable information
found.
TSCA: All components of this product are on the TSCA
Inventory or are exempt
from TSCA Inventory requirements.
CEPA (DSL) : All components of this product are on the DSL inventory or are
exempt from
reporting under the New Substances Notification Regulations.
DOT: No applicable information
found.
PROPER SHIPPING NAME: Not
applicable.
HAZARDOUS CLASS: Not applicable.
LABEL REQUIRED: Not applicable.
IDENTIFICATION NUMBER: Not
applicable.
OTHER PERTINENT INFORMATION: Not
applicable.
SECTION
XI - SPECIAL
PRECAUTIONS
AND COMMENTS
PRECAUTIONS TO BE TAKEN IN
HANDLING AND
STORING:
Keep away from eyes. Avoid prolonged contact with
skin.
Wash exposed skin with soap and water. Avoid breathing of
mist.
OTHER PRECAUTIONS: Not
applicable.
REGISTRATION/CERTIFICATIONS:
Not applicable.
This information is furnished without
warranty,
representation,
inducement or license of any kind, except that it is accurate to the
best
of Flame Seal Products, Inc. knowledge, or obtained from sources
believed
by Flame Seal Products, Inc. to be accurate, and Flame Seal Products,
Inc.
does not assume any legal responsibility for use or reliance upon same.
Customers are encouraged to conduct their own tests. Before using any
product,
read its label.
EFFECTIVE DATE: April 25, 2010
SUPERSEDES: May 10, 2010
|