"THE ABSOLUTE BEST IN
FIRE PROTECTION TECHNOLOGY™"
( Complete TESTS located at the bottom of Each Description Page.)
|
|
|
|
| TESTS PASSED: |
AT THE BOTTOM OF EACH DESCRIPTION PAGE |
. |
| UL723;
ASTM E-84; NFPA 255; UBC 42-1; (Steiner Tunnel Test)... |
FX-100® Coating on Douglas Fir | Class A:
Flame Spread = 5 Smoke Generation = 20 |
| UL 94VO Plastic
Test, ASTM-E662 Test done by Minnetech Corp., Minneapolis, MN |
FX-PL® Coating on ABS Plastic | Passed |
| UL723;
ASTM E-84; NFPA 255; UBC 42-1; (Steiner Tunnel Test)... |
WOOD SEAL™ on Douglas Fir | Class B: (Class A shown below): Flame Spread = 35 Smoke Generation = 95 |
| DIVERSIFIED TESTING LABS: | . | . |
| NFPA 701 Upholstery Fabric | FABRIC SEAL™(S) on Cotton / Polyester | Passed |
| FAA Federal Aviation Test FAR 25.853 | FABRIC SEAL™(S) on Cotton / Polyester | Passed |
| UFAC Upholstered Furniture Action Council Test - Vertical Flame Test | FABRIC SEAL™(S) on Cotton / Polyester | Class I |
| Butane Flame - British Standards 5852 (British Test-Samples dry cleaned as part of test) | FABRIC SEAL™(S) on Cotton / Polyester | Passed |
| Cigarette -
British Standards
5852 (British Test-Samples Dry cleaned as part of test) |
FABRIC SEAL™(S) on Cotton / Polyester | Passed |
| FAA Compartment Interiors - 60 Sec. | LEATHER SEAL™ on Leather | Passed - no afterflame, no drip |
| MVS Motor Vehicle Safety Stnd.. #302 | LEATHER SEAL™ on Leather | Passed |
| California USA Tech Bulletin 117 Sec. E | LEATHER SEAL™ on Leather | DNI (Did Not Ignite) |
| UFAC Upholstered Furniture Action Council Test | LEATHER SEAL™ on Leather | Class 1 |
| NFPA 701 Flame Propagation of Textiles and Films |
PAPER SEAL™ on Paper | Passed - No Flame |
| INTERTEK TESTING LABS (was OMEGA POINT LABS): | . | . |
| UL 723; ASTM
E-84, NFPA
255; UBC 42-1... Uniform Building Code |
FX-100® Coating on Pine Plywood (with flame at butt joint) | Class A:
Flame Spread = 5 Smoke Generation = 40 |
| UL723;
ASTM E-84; NFPA 255; UBC 42-1; (Steiner Tunnel Test)... |
WOOD
SEAL™- A Liquid : on
Douglas Fir (Adobe PDF format) |
Class A:
Flame Spread = 25 Smoke Generation = 50 |
| ASTM E-119
Furnace Test
for fire protection of Electrical Conduits and Cable Trays in Nuclear
Power
Plants. Tested as per NFPA 251 standard for Appendix R guidelines set
forth
by the NRC over 3 inch conduit (empty) ), covered with Thermolag. |
FBS® SYSTEM
WRAP: A wrap
system for Conduits & Cable Trays. |
Passed 3 hour -
an upgrade as an overlay for Thermolag. |
|
FBS® 60 SYSTEM WRAP: 4 inch fiberglass electrical conduit filled with Power, Control, and Instrumentation Cables. | Passed 1 hour |
| FLAME SEAL PRODUCTS: | . | . |
| UL-1709 | FBS® SYSTEM WRAP on 2 inch Steel Conduit | Passed 30 minutes witnessed by 7 Oil Companies. |
| STERIGENICS | . | . |
| Radiation Exposure and Accelerated Aging 10.68 M RAD's | FBS® SYSTEM and FX100® COATING | Passed - zero % loss of intumescent values |
List Revision: REV. 12-5-05 ( Complete TESTS located at the bottom of Each Description Page.) Testing
Laboratory Links:
Omega Point Laboratory-
www.opl.com,
South West Research Testing - www.swresearch.com,
Sterigenics (IBA) www.sterigenics.com
Diversified Testing Laboratories - no www. at this time
Ph: 336-227-7710.
CREDIT CARDS ACCEPTED : ![]() ® Registered in US Patent and Trademark Office ™ Trademark of FLAME SEAL PRODUCTS INC. (Non Toxic, Non
Hazardous, No
PBDEs - Polybrominated diphenyl ethers)
|